CFD Analysis Of Ashghal Tunnel | Case Study

Fluid Codes carried out the study of a truck fire and smoke dispersion, in a total of three road tunnels located in Doha, Qatar. The design of a ventilation system for tunnels (Induction fans) which should inject fresh air along the tunnel with a certain velocity (critical velocity) is an important task for effective management of fire events.
FEA For Lifting Of Top Portion OF Sphere For Erections | Case Study

In this case study, Fluid Codes team supported ENOC with the project “Lifting of Top Portion OF Sphere for Erections”. Discover challenges and engineering solution.
Reactor Tank With Agitator | Case Study

A CFD analysis was carried out for a reactor tank with agitator by Fluid Codes team . FEA analysis was also performed for the shaft and agitator in order to predict the failure of agitator blades. Fluid-structure interaction was the key point for this analysis, by mapping the pressure loads from CFD as loads (inputs) for the FEA Analysis.
Misdistribution Header System | Case Study

Part of the piping system was developed by Petrofac, feeding two separators. The objective of this case study was to find out more about the fluid distribution conditions through the piping system and to predict the multiphase fluid flow rates passing to each separator under different operating conditions. Read this case study to find out engineering solution done by Fluid Codes team.
CFD Analysis For Smoke Extraction System Of The MERAAS Outlet Village Mall | Case Study

Fluid Codes was engaged in to carry out a CFD study for smoke extraction in the Meraas Outlet Village Mall, which was in the final construction stage. The simulation was carried out to validate the performance of smoke extraction system within the mall, for two different fire scenarios at different instances.
Smoke & Ventilation Analysis Dubai Airport Terminal 3 | Case Study

Dar Al-Handasah, an internationally recognized engineering firm, was involved in the design and construction of Terminal 3 concourse at Dubai International Airport. As part of the project, ANSYS CFD was used to design the ventilation system and validate the safety and thermal comfort within the concourse.
Effect Of The Air Quality Due To Car Park Shaft Exit | Case Study

CFD is now a commonly used tool for assessing atmospheric dispersion of pollutants from stacks. Fluid Codes was engaged to study the dispersion of CO released from a car park exhaust system onto a newly proposed building to be positioned directly adjacent. The client was concerned about that the new building, which was in a planning stage, could potentially be immersed in high concentrations of CO.
FEA Of A Horizontal Pressure Vessel | Case Study

In this study, the evaluation of nozzle- shell junction of a horizontal pressure vessel was performed using finite element analysis. High stress at the nozzle to head or shell junction area are common. Due to discontinuity of the geometry, the defect can occur and the junction region can become the weakest point, which will be the source of failure of the whole structure. Find out engineering solution in this case study.
Saipem Meg And Solvent Mixing | Case Study

Fluid Codes supported SAIPEM with the model injection of thinning solvent into existing gas piping system. Read this case study to find our engineering solution.
FEA Of Column For GASCO | Case Study

Gasco required to study an existing column built in 1978, which was heavily corroded and some places replaced with new sheet metal. The goal was to verify the integrity of the renovated column with the various working conditions and loads, internal pressure, packing load, nozzle load, platform load, pipe support, insulation, operating liquid and self-weight. Find our engineering solution that was done by Fluid Codes team.